C15801 | error history, C15805 | service code, C15810 | service code – Lenze E94AYAE SM301 User Manual
Page 96: 5parameter reference
5
Parameter reference
5.1
Parameter list | C15801
96
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15801
C15805
C15810
Parameter | Name:
C15801 | Error history
Data type: UNSIGNED_16
Index: 8774
d
= 2246
h
List with internal error numbers for service operations.
Please forward error history to the Lenze Service on request.
Note:
The universally valid error messages of the safety module are entered in code C00168 and in the logbook of the
controller. Details relating to this are described in the "
" chapter.
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C15801/1
Error history 1
C15801/2
Error history 2
C15801/3
Error history 3
C15801/4
Error history 4
C15801/5
Error history 5
C15801/6
Error history 6
C15801/7
Error history 7
C15801/8
Error history 8
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15805 | Service code
Data type: UNSIGNED_32
Index: 8770
d
= 2242
h
Display of information if parameter set was not successfully checked for plausibility.
Display range
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
C15805/1
Service code
C15805/2
Service code
C15805/3
Service code
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15810 | Service code
Data type: BITFIELD_32
Index: 8765
d
= 223D
h
Display of internal control words.
Display range
0x00000000
0xFFFFFFFF
Value is bit-coded:
Info
Bit 0 STO
Bit 1 SS1
Bit 2 SS2
Bit 3 SLS1
Bit 4 SLS2
(from V1.1)
Bit 5 SLS3
(from V1.1)
Bit 6 SLS4
(from V1.1)