C15893 | log status, C15893, C15893/1 – Lenze E94AYAE SM301 User Manual
Page 100: 5parameter reference

5
Parameter reference
5.1
Parameter list | C15893
100
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15893
Parameter | Name:
C15893 | Log status
Data type: BITFIELD_64
Index: 8682
d
= 21EA
h
From V1.4
Logged status.
Value is bit-coded:
Info
Bit 0 STO via SD-In
STO was triggered via a safe input.
Bit 1 STO via S-bus
STO was triggered via the safety bus.
Bit 2 STO by error
STO was triggered by an error.
Bit 3 Reserved
Bit 4 SS1 via SD-In
SS1 was triggered via a safe input.
Bit 5 SS1 via S-bus
SS1 was triggered via the safety bus.
Bit 6 SS1 by error
SS1 was triggered by an error.
Bit 7 Reserved
Bit 8 SS2 via SD-In
SS2 was triggered via a safe input.
Bit 9 SS2 via S-bus
SS2 was triggered via the safety bus.
Bit 10 SS2 by error
SS2 was triggered by an error.
Bit 11 Reserved
Bit 12 SLS1 via SD-In
SLS1 was triggered via a safe input.
Bit 13 SLS1 via S-bus
SLS1 was triggered via the safety bus.
Bit 14 SLS1 via OMS
SLS1 was triggered via the operating mode changeover.
Bit 15 Reserved
Bit 16 SLS2 via SD-In
SLS2 was triggered via a safe input.
Bit 17 SLS2 via S-bus
SLS2 was triggered via the safety bus.
Bit 18 SLS2 via OMS
SLS2 was triggered via the operating mode changeover.
Bit 19 Reserved
Bit 20 SLS3 via SD-In
SLS3 was triggered via a safe input.
Bit 21 SLS3 via S-bus
SLS3 was triggered via the safety bus.
Bit 22 SLS3 via OMS
SLS3 was triggered via the operating mode changeover.
Bit 23 Reserved
Bit 24 SLS4 via SD-In
SLS4 was triggered via a safe input.
Bit 25 SLS4 via S-bus
SLS4 was triggered via the safety bus.
Bit 26 SLS4 via OMS
SLS4 was triggered via the operating mode changeover.
Bit 27 Reserved
Bit 28 SDIpos via SD-In
SDIpos was triggered via a safe input.
Bit 29 SDIpos via S-bus
SDIpos was triggered via the safety bus.
Bit 30 SDIpos via SLS
SDIpos was triggered in combination with SLS.
Bit 31 SDIpos in normal operation
SDIpos was triggered during normal operation.
Bit 32 SDIneg via SD-In
SDIneg was triggered via a safe input.
Bit 33 SDIneg via S-bus
SDIneg was triggered via the safety bus.
Bit 34 SDIneg via SLS
SDIneg was triggered in combination with SLS.
Bit 35 SDIneg in normal operation
SDIneg was triggered during normal operation.
Bit 36 SLI active
SLI was triggered during special operation.
Bit 37 Reserved
Bit 38 Reserved