6error messages – Lenze E94AYAE SM301 User Manual
Page 107
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
107
6
Error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19857577
Module ID unequal effective safety address
Warning
19857568
New parameter set deleted
Information
19857569
New safety parameter set loaded
Information
19857515
No encoder system configured
Warning
19857572
No safe parameter set for safety module
Warning
19857576
Parameter set communicaton error
Information
19857575
Parameter set plausibility error
Warning
19857442
PROFIsafe - communication error
Information
19857446
PROFIsafe - invalid data
Information
19857479
PROFIsafe CRC1 error
Information
19857445
PROFIsafe has left data exchange
Information
19857444
PROFIsafe passivated
Information
19857600
Reference voltage error
Warning
19857480
Reserved (PROFIsafe standard)
Information
19857481
Reserved (PROFIsafe standard)
Information
19857482
Reserved (PROFIsafe standard)
Information
19857616
Safe speed invalid
Warning
19857441
Safety address invalid (0 or FFFFhex)
Warning
19857573
Safety parameter set defect
Warning
19857512
SDIneg: Wrong direction
Warning
19857511
SDIpos: Wrong direction
Warning
19857497
Short circuit / cross-circuit - SD-Out
Warning
19857519
SLI: Safely limited increment exceeded
Warning
19857510
SLS/SMS: Error stop not executed
Warning
19857506
SLS1: Nlim1 exceeded
Warning
19857507
SLS2: Nlim2 exceeded
Warning
19857508
SLS3: Nlim3 exceeded
Warning
19857509
SLS4: Nlim4 exceeded
Warning
19857513
SMS: Nmax exceeded
Warning
19857514
SOS: Tolerance limit exceeded
Warning
19857518
SS1/SS2: Speed ramp exceeded
Warning
19857505
SS1/SS2: Stopping time exceeded
Warning
19857617
SSM: Encoder error
Warning
19857619
SSM: Error - standard device data
Warning
19857618
SSM: Resolver error
Warning
19857620
SSM: Speed comparison error
Warning
19857621
SSM: Synchronisation error
Warning
19857622
SSM: Wrong PDO version
Warning
19857552
Stuck at High at SD-In1, channel A
Warning
19857553
Stuck at High at SD-In1, channel B
Warning
19857554
Stuck at High at SD-In2, channel A
Warning
19857555
Stuck at High at SD-In2, channel B
Warning
19857556
Stuck at High at SD-In3, channel A
Warning
19857557
Stuck at High at SD-In3, channel B
Warning
19857558
Stuck at High at SD-In4, channel A
Warning
19857559
Stuck at High at SD-In4, channel B
Warning
19857536
Stuck at High SD-Out1, channel A
Warning
19857538
Stuck at High SD-Out1, channel B
Warning
19857537
Stuck at Low SD-Out1, channel A
Warning
19857539
Stuck at Low SD-Out1, channel B
Warning
19857425
Synchronisation error - standard device
Information
19857502
Test pulse error - internal disconnecting path
Warning
hex
dec
Error message
Response (Lenze setting)