C15317 | ss1, ss2: ramp - start-offset, C15320 | sms: maximum speed nmax, C15321 | sms: reaction (n>nmax) – Lenze E94AYAE SM301 User Manual
Page 89: C15330 | sls: limited speed nlim, C15317, The tolerance w, C15321, C15330/1, C15330/2, C15330/3

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
89
5
Parameter reference
5.1
Parameter list | C15317
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15317
C15320
C15321
C15330
Parameter | Name:
C15317 | SS1, SS2: Ramp - start-offset
Data type: UNSIGNED_8
Index: 9258
d
= 242A
h
From V1.4
Speed offset for the start of ramp monitoring.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
30 0 %
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15320 | SMS: Maximum speed Nmax
Data type: UNSIGNED_16
Index: 9255
d
= 2427
h
Activation of the SMS function and selection of the maximum speed.
• The setting Nmax = 0 deactivates the function.
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
16000 1 rpm
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15321 | SMS: Reaction (n>Nmax)
Data type: UNSIGNED_8
Index: 9254
d
= 2426
h
Reaction to exceeding the set maximum speed Nmax.
Selection list
(Lenze setting printed in bold)
Info
0 STO
1 SS1
2 SS2
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15330 | SLS: Limited speed Nlim
Data type: UNSIGNED_16
Index: 9245
d
= 241D
h
Setting of the safely limited speed.
Setting range
(min. value | unit | max. value)
0
rpm
16000
Subcodes
Lenze setting
Info
C15330/1
0 rpm
SLS1: Limited speed Nlim1
C15330/2
0 rpm
SLS2: Limited speed Nlim2
(from V1.1)
C15330/3
0 rpm
SLS3: Limited speed Nlim3
(from V1.1)
C15330/4
0 rpm
SLS4: Limited speed Nlim4
(from V1.1)
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1