Sos: tolerance limit exceeded [0x012f006a, No encoder system configured [0x012f006b, Cas: circulation time exceeded [0x012f006c – Lenze E94AYAE SM301 User Manual
Page 118: Cas: hardware or discrepancy error [0x012f006d, 0x012f006c, 0x012f006d, 0x012f006b, 0x012f006a, 6error messages
6
Error messages
118
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
SOS: Tolerance limit exceeded [0x012f006a]
No encoder system configured [0x012f006b]
CAS: Circulation time exceeded [0x012f006c]
CAS: Hardware or discrepancy error [0x012f006d]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
106
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The drive has exceeded a tolerance limit for the SOS
function.
• Adapt tolerance limits or increase distance to the
parameterised limits.
• Adapt response time of encoder monitoring.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
107
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
A speed- or position-based safety function is tried to be
carried out without an encoder having been configured.
Configuration of an encoder system valid for safety-
related applications.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
108
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The maximum time between the activation and
feedback of cascading has been exceeded.
• Input delay for SD-In4 must be parameterised lower
than or equal to 10 ms.
• Check wiring between the cascaded modules.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
109
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The cascading output has not been deactivated by the
hardware quickly enough, or there is a discrepancy at the
cascading input.
• Check wiring between the cascaded modules.
• Replace safety module.