C15311 | sos: tolerance margin (delta p=0), C15312 | sos: maximum position change, C15315 | ss1, ss2: ramp monitoring – Lenze E94AYAE SM301 User Manual
Page 88: C15316 | ss1, ss2: ramp - s-ramp time, C15311, C15315, C15316, C15312, 5parameter reference
5
Parameter reference
5.1
Parameter list | C15311
88
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15311
C15312
C15315
C15316
Parameter | Name:
C15311 | SOS: Tolerance margin (delta p=0)
Data type: UNSIGNED_32
Index: 9264
d
= 2430
h
From V1.3
Safely monitored tolerance margin for zero position change.
Setting range
(min. value | unit | max. value)
Lenze setting
0
Incr.
327680 0 incr.
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15312 | SOS: Maximum position change
Data type: UNSIGNED_32
Index: 9263
d
= 242F
h
From V1.3
Value of the maximum position change while SOS has been active.
Display range
(min. value | unit | max. value)
0
Incr.
2147483647
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15315 | SS1, SS2: Ramp monitoring
Data type: UNSIGNED_8
Index: 9260
d
= 242C
h
From V1.4
Selection for whether the deceleration ramp is to be monitored when SS1 and SS2 are executed.
Selection list
(Lenze setting printed in bold)
Info
0 No ramp monitoring
1 Ramp monitoring activated
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15316 | SS1, SS2: Ramp - S-ramp time
Data type: UNSIGNED_8
Index: 9259
d
= 242B
h
From V1.4
S-ramp time of the deceleration ramp for SS1 and SS2 if no linear ramp is used.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 0 %
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1