F_crc_length error [0x012f0045, F parameter version is incorrect [0x012f0046, Profisafe crc1 error [0x012f0047 – Lenze E94AYAE SM301 User Manual
Page 114: Reserved (profisafe standard) [0x012f0048, Reserved (profisafe standard) [0x012f0049, 0x012f0045, 0x012f0046, 0x012f0047, 0x012f0048, 0x012f0049
6
Error messages
114
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
F_CRC_Length error [0x012f0045]
F parameter version is incorrect [0x012f0046]
PROFIsafe CRC1 error [0x012f0047]
Reserved (PROFIsafe standard) [0x012f0048]
Reserved (PROFIsafe standard) [0x012f0049]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
69
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The data length of the F_CRC of the control system is
faulty.
Check the safety parameters in the control system.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
70
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The F parameter version is incorrect and not supported
by the safety module.
Select a permissible F parameter version in the control
system.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
71
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
PROFIsafe-CRC1 error. Current F parameter CRC is faulty.
• Check F parameter CRC (CRC1) in the control system.
• Check GSD file.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
72
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
--
--
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
73
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
--
--