_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15501
C15502
C15800
Parameter | Name:
C15501 | Position encoder gearbox factor
Data type: UNSIGNED_16
Index: 9074
d
= 2372
h
From V1.3
Setting of the gearbox factor between motor and position encoder.
Safe speed measurement and position detection
Setting range
(min. value | unit | max. value)
Lenze setting
20
%
50000 100 %
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15502 | Position encoder mounting direction
Data type: UNSIGNED_8
Index: 9073
d
= 2371
h
From V1.3
Setting of the mounting direction of the position encoder referred to the motor encoder.
Safe speed measurement and position detection
Selection list
(Lenze setting printed in bold)
0 Like motor encoder
1 Inverse to motor encoder
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15800 | Current error type
Data type: UNSIGNED_8
Index: 8775
d
= 2247
h
Type of the currently pending error.
Selection list
(read only)
0 No error
1 Warning
2 Trouble
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1