Stuck at high at sd-in2, channel b [0x012f0093, Stuck at high at sd-in3, channel a [0x012f0094, Stuck at high at sd-in3, channel b [0x012f0095 – Lenze E94AYAE SM301 User Manual
Page 121: Stuck at high at sd-in4, channel a [0x012f0096, Stuck at high at sd-in4, channel b [0x012f0097, 0x012f0093, 0x012f0094, 0x012f0095, 0x012f0096, 0x012f0097

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
121
6
Error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Stuck at High at SD-In2, channel B [0x012f0093]
Stuck at High at SD-In3, channel A [0x012f0094]
Stuck at High at SD-In3, channel B [0x012f0095]
Stuck at High at SD-In4, channel A [0x012f0096]
Stuck at High at SD-In4, channel B [0x012f0097]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
147
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel B of input SD-In2 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
148
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel A of input SD-In3 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
149
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel B of input SD-In3 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
150
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel A of input SD-In4 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
151
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel B of input SD-In4 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.