3safe configuration – Lenze E94AYAE SM301 User Manual
Page 35

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
35
3
Safe configuration
3.7
Safe inputs
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of "Safe inputs" parameter group:
Sensor type/sensor function
The sensor type and function can be parameterised.
Tip!
Detailed information on sensor inputs, active and passive sensors can be found in the
manual for the safety module.
Parameter
Info
Lenze setting
Value Unit
SD-In1...4 sensor type
Input deactivated
SD-In1...4 sensor function
Free assignment
SD-In1...4 free assignment
SD-In1...4 discrepancy time
10 ms
SD-In1...4 input delay
0 ms
Note!
If an error (e.g. a discrepancy error) occurs at a safe input to which the "operation mode
selector" sensor function is assigned, the corresponding input is valued as OFF state.
• By this, normal operation is activated
up to SM301 V1.2
.
•
From SM301 V1.3
the operating mode in the case of LOW level at the safe input can
be parameterised via
• The "Module Error ME" LED blinks,
is not tripped.
• Special operation can only be selected again if the error has been eliminated and
acknowledged.