C15115 | s bus: control data display, C15115, 5parameter reference – Lenze E94AYAE SM301 User Manual
Page 84

5
Parameter reference
5.1
Parameter list | C15115
84
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15115
Parameter | Name:
C15115 | S bus: Control data display
Data type: BITFIELD_32
Index: 9460
d
= 24F4
h
From V1.2
Display of the safety bus control data after being filtered via
Display range
0x00000000
0xFFFFFFFF
Value is bit-coded:
Info
Bit 0 STO
Bit 1 SS1
Bit 2 SS2
Bit 3 SLS1
Bit 4 SLS2
(from V1.1)
Bit 5 SLS3
(from V1.1)
Bit 6 SLS4
(from V1.1)
Bit 7 SDIpos
(from V1.3)
Bit 8 SDIneg
(from V1.3)
Bit 9 ES
Bit 10 Reserved
Bit 11 OMS
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Bit 16 PS_AIS
Restart acknowledgement via safety bus
Bit 17 PS_AIE
Error acknowledgement via safety bus
Bit 18 Reserved
Bit 19 Reserved
Bit 20 Reserved
Bit 21 Reserved
Bit 22 Reserved
Bit 23 SSE
Bit 24 SD-Out1
Bit 25 Reserved
Bit 26 Reserved
Bit 27 Reserved
Bit 28 Reserved
Bit 29 Reserved
Bit 30 Reserved
Bit 31 Reserved
Read access Write access CINH PLC-STOP No transfer