C15331 | sls: braking time nlim, C15332 | sls: reaction (n>nlim), C15333 | sls: permissible direction of movement – Lenze E94AYAE SM301 User Manual
Page 90: C15331/1, C15332/1, C15333/1, C15331/2, C15332/2, C15333/2, C15331/3

5
Parameter reference
5.1
Parameter list | C15331
90
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15331
C15332
C15333
Parameter | Name:
C15331 | SLS: Braking time Nlim
Data type: UNSIGNED_16
Index: 9244
d
= 241C
h
Safely monitored time for braking the drive below the limited speed set in
.
Setting range
(min. value | unit | max. value)
0
ms
30000
Subcodes
Lenze setting
Info
C15331/1
0 ms
SLS1: Braking time Nlim1
C15331/2
0 ms
SLS2: Braking time Nlim2
(from V1.1)
C15331/3
0 ms
SLS3: Braking time Nlim3
(from V1.1)
C15331/4
0 ms
SLS4: Braking time Nlim4
(from V1.1)
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15332 | SLS: Reaction (n>Nlim)
Data type: UNSIGNED_8
Index: 9243
d
= 241B
h
Response carried out in the safety module when the limited speed is exceeded.
Selection list
Info
0 STO
1 SS1
2 SS2
Subcodes
Lenze setting
Info
C15332/1
1: SS1
SLS1: Response (n>Nlim1)
C15332/2
1: SS1
SLS2: Response (n>Nlim2)
(from V1.1)
C15332/3
1: SS1
SLS3: Response (n>Nlim3)
(from V1.1)
C15332/4
1: SS1
SLS4: Response (n>Nlim4)
(from V1.1)
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15333 | SLS: Permissible direction of movement
Data type: UNSIGNED_8
Index: 9242
d
= 241A
h
From V1.3
Permissible direction of movement when monitoring SLS.
Selection list
0 Both directions enabled
1 Positive direction enabled
2 Negative direction enabled
Subcodes
Lenze setting
Info
C15333/1
0: Both directions enabled
SLS1: Permissible direction of movement
C15333/2
0: Both directions enabled
SLS2: Permissible direction of movement
C15333/3
0: Both directions enabled
SLS3: Permissible direction of movement
C15333/4
0: Both directions enabled
SLS4: Permissible direction of movement
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1