beautypg.com

Reference voltage error [0x012f00c0, 6v voltage error [0x012f00c1, 0x012f00c1 – Lenze E94AYAE SM301 User Manual

Page 124: 0x012f00a9, 0x012f00a8, 0x012f00c0, 6error messages

background image

6

Error messages

124

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Safety parameter set communicaton error [0x012f00a8]

Module ID unequal effective safety address [0x012f00a9]

Reference voltage error [0x012f00c0]

6V voltage error [0x012f00c1]

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

168

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

A communication error has occurred when loading the

parameter set.

• Check whether memory module and safety module

have been installed correctly.

• Repeat parameter set transfer.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

169

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The module ID in the parameter set does not correspond

to the effective safety address.

Adjust module ID, safety address and DIP switch for

setting the safety address.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

192

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The threshold value of the reference voltage in the safety

module has been exceeded or fallen below the limit

value.

Replace safety module.

Module ID (decimal)

Error ID (decimal)

303: SM301 safety module

193

Response (Lenze setting printed in bold)

None  System error  Error  Fault  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The threshold value of the 6 V voltage in the safety

module has been exceeded or fallen below the limit

value.

Replace safety module.