5parameter reference, 2 table of attributes 104, Table of attributes – Lenze E94AYAE SM301 User Manual
Page 104

5
Parameter reference
5.2
Table of attributes
104
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Table of attributes
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH
Status of safety functions
9575
2567
E
1
BITFIELD_32
Command status
9572
2564
E
1
UNSIGNED_16
1
Parameter set status
9565
255D
E
1
UNSIGNED_8
1
Parameter CRC
9564
255C
A
2
UNSIGNED_32
1
Parameter set creation time
9562
255A
E
1
UNSIGNED_64
1
Time of RTC parameter setting
9561
2559
E
1
VISIBLE_STRING
Time of sec. parameter setting
9560
2558
E
1
UNSIGNED_32
1
Parameter set version
9559
2557
E
1
UNSIGNED_8
1
Stored module ID
9558
2556
E
1
UNSIGNED_16
1
SD-In Sensor type
9545
2549
A
4
UNSIGNED_8
1
SD-In Sensor function
9544
2548
A
4
UNSIGNED_8
1
SD-In Free assignment
9543
2547
A
4
UNSIGNED_8
1
SD-In Discrepancy time
9542
2546
A
4
UNSIGNED_16
1
SD-In Input delay
9541
2545
A
4
UNSIGNED_8
1
CAS: Cascading
9540
2544
E
1
UNSIGNED_8
1
CAS: Stop delay
9539
2543
E
1
UNSIGNED_16
1
Input image
9535
253F
E
1
BITFIELD_32
SD-Out switching condition
9524
2534
A
1
BITFIELD_32
SD-Out switching condition
9523
2533
A
1
BITFIELD_32
SD-Out logic function
9520
2530
A
1
UNSIGNED_8
1
Output image
9515
252B
E
1
BITFIELD_16
S-bus: configuration
9475
2503
E
1
UNSIGNED_8
1
Current DIP switch display
9474
2502
E
1
UNSIGNED_16
1
Safety address
9464
24F8
E
1
UNSIGNED_16
1
Effective safety address
9463
24F7
E
1
UNSIGNED_16
1
S bus: Filter control data
9462
24F6
E
1
BITFIELD_32
S-bus: Display of control data
9460
24F4
E
1
BITFIELD_32
OMS: Stop function
9375
249F
E
1
UNSIGNED_8
1
OMS: Motion function
9374
249E
E
1
UNSIGNED_8
1
OMS: Function at LOW level
9373
249D
E
1
UNSIGNED_8
1
SLI: Safely limited increment
9372
249C
E
1
UNSIGNED_32
1
SLI: Value of position change
9371
249B
E
1
UNSIGNED_32
1
SSE: Emergency stop function
9370
249A
E
1
UNSIGNED_8
1
Restart behaviour
9275
243B
A
2
UNSIGNED_8
1
SS1, SS2: Stopping time
9270
2436
E
1
UNSIGNED_16
1
SS1 mode
9269
2435
E
1
UNSIGNED_8
1
SS1: STO delay after n=0
9268
2434
E
1
UNSIGNED_16
1
SS2 mode
9267
2433
E
1
UNSIGNED_8
1
Speed window (n=0)
9265
2431
E
1
UNSIGNED_16
1
SOS: Tolerance margin (delta p=0) *
9264
2430
E
1
UNSIGNED_32
1
SOS: Maximum position change
9263
242F
E
1
UNSIGNED_32
1
SS1, SS2: Ramp monitoring
9260
242C
E
1
UNSIGNED_8
1
SS1, SS2: Ramp S-ramp time
9259
242B
E
1
UNSIGNED_8
1
SS1, SS2: Ramp offset start
9258
242A
E
1
UNSIGNED_8
1
SMS: Max. speed Nmax
9255
2427
E
1
UNSIGNED_16
1
SMS: Reaction (n>Nmax)
9254
2426
E
1
UNSIGNED_8
1
SLS: Limited speed Nlim
9245
241D
A
4
UNSIGNED_16
1
SLS: Braking time Nlim
9244
241C
A
4
UNSIGNED_16
1
SLS: Reaction (n>Nlim)
9243
241B
A
4
UNSIGNED_8
1