C15402 | actual speed - n_safe, C15405 | internal actual speed value, C15409 | motor mounting direction – Lenze E94AYAE SM301 User Manual
Page 93: C15410 | response time of encoder monitoring, C15409, D via, C15410, 5parameter reference

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
93
5
Parameter reference
5.1
Parameter list | C15402
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15402
C15405
C15409
C15410
Parameter | Name:
C15402 | Actual speed - n_safe
Data type: INTEGER_16
Index: 9173
d
= 23D5
h
Display of the current speed calculated by the safety module.
Safe speed measurement and position detection
Display range
(min. value | unit | max. value)
-16000
rpm
16000
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15405 | Internal actual speed value
Data type: INTEGER_16
Index: 9170
d
= 23D2
h
From V1.4
Internal actual speed values of the SM301.
Safe speed measurement and position detection
Display range
(min. value | unit | max. value)
-16000
rpm
16000
Subcodes
Info
C15405/1
Internal actual speed value nSM determined from the
motor position.
C15405/2
Internal actual speed value nGG determined from the
position data of the standard device.
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15409 | Motor mounting direction
Data type: UNSIGNED_8
Index: 9166
d
= 23CE
h
From V1.4
Setting of the motor mounting direction.
Safe speed measurement and position detection
Selection list
(Lenze setting printed in bold)
0 Motor rotating CW
1 Motor rotating CCW
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15410 | Response time of encoder monitoring
Data type: UNSIGNED_8
Index: 9165
d
= 23CD
h
From V1.2
Response time of encoder monitoring.
Safe speed measurement and position detection
Selection list
(Lenze setting printed in bold)
0 12ms
10 50ms
20 100 ms
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1