Stuck at high sd-out1, channel b [0x012f0082, Stuck at low sd-out1, channel b [0x012f0083, Stuck at high at sd-in1, channel a [0x012f0090 – Lenze E94AYAE SM301 User Manual
Page 120: Stuck at high at sd-in1, channel b [0x012f0091, Stuck at high at sd-in2, channel a [0x012f0092, 0x012f0090, 0x012f0091, 0x012f0092, 0x012f0082, 0x012f0083

6
Error messages
120
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Stuck at High SD-Out1, channel B [0x012f0082]
Stuck at Low SD-Out1, channel B [0x012f0083]
Stuck at High at SD-In1, channel A [0x012f0090]
Stuck at High at SD-In1, channel B [0x012f0091]
Stuck at High at SD-In2, channel A [0x012f0092]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
130
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel B of output SD-Out1 cannot be deactivated.
Check wiring at the output SD-Out1 for short circuit.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
131
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel B of output SD-Out1 cannot be activated.
Check supply voltage and wiring for the safe output.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
144
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel A of input SD-In1 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
145
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel B of input SD-In1 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
146
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel A of input SD-In2 cannot be deactivated.
• Check wiring at the safe input for short circuit.
• Check configuration for the safe input.