5v voltage error [0x012f00c2, 6v voltage error [0x012f00c3, Safe speed invalid [0x012f00d0 – Lenze E94AYAE SM301 User Manual
Page 125: Ssm: encoder error [0x012f00d1, Ssm: resolver error [0x012f00d2, 0x012f00c2, 0x012f00c3, 0x012f00d0, 0x012f00d1, 0x012f00d2
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
125
6
Error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5V voltage error [0x012f00c2]
2.6V voltage error [0x012f00c3]
Safe speed invalid [0x012f00d0]
SSM: Encoder error [0x012f00d1]
SSM: Resolver error [0x012f00d2]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
194
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The threshold value of the 5 V-reference voltage in the
safety module has been exceeded or fallen below the
limit value.
Replace safety module.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
195
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The threshold value of the 2.6 V voltage in the safety
module has been exceeded or fallen below the limit
value.
Replace safety module.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
208
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
It is not possible to detect a safe speed.
• Check encoder systems used.
• Check communication between the drive and the
safety module.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
209
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Error in safe speed monitoring via encoder.
Check configuration and connection of the encoder used.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
210
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Error in safe speed monitoring via resolver.
Check configuration and connection of the encoder used.