C15306 | ss1 mode, C15307 | ss1: sto delay after n=0, C15308 | ss2 mode – Lenze E94AYAE SM301 User Manual
Page 87: C15310 | speed window (n=0), C15306, C15307, C15308, C15310, C15320, 5parameter reference

Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
87
5
Parameter reference
5.1
Parameter list | C15306
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15306
C15307
C15308
C15310
Parameter | Name:
C15306 | SS1 mode
Data type: UNSIGNED_8
Index: 9269
d
= 2435
h
From V1.3
Selection whether STO is already activated after reaching n=0 when SS1 is executed or only after the parameterised
stopping time.
Selection list
(Lenze setting printed in bold)
0 STO after stopping time
1 STO when n=0
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15307 | SS1: STO delay after n=0
Data type: UNSIGNED_16
Index: 9268
d
= 2434
h
From V1.3
Delay time after detection of n=0 until activation of STO.
• Only relevant if "SS1 mode" = "STO with n=0" and operation with encoder system.
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
30000 0 ms
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15308 | SS2 mode
Data type: UNSIGNED_8
Index: 9267
d
= 2433
h
From V1.3
Selection whether SOS is already activated after reaching n=0 when SS2 is executed or only after the parameterised
stopping time.
Selection list
(Lenze setting printed in bold)
0 SOS after stopping time
1 SOS when n=0
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15310 | Speed window (n=0)
Data type: UNSIGNED_16
Index: 9265
d
= 2431
h
Tolerance window for zero speed.
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
16000 0 rpm
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1