Ss1/ss2: speed ramp exceeded [0x012f006e, Sli: safely limited increment exceeded [0x012f006f, Stuck at high sd-out1, channel a [0x012f0080 – Lenze E94AYAE SM301 User Manual
Page 119: Stuck at low sd-out1, channel a [0x012f0081, 0x012f006f, 0x012f006e, 0x012f0080, 0x012f0081, 6error messages
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
119
6
Error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
SS1/SS2: Speed ramp exceeded [0x012f006e]
SLI: Safely limited increment exceeded [0x012f006f]
Stuck at High SD-Out1, channel A [0x012f0080]
Stuck at Low SD-Out1, channel A [0x012f0081]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
110
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The monitoring of the speed ramp is activated. When the
SS1/SS2 stop function is executed, the deceleration of
the speed ramp is monitored. If the monitoring limits are
exceeded, an error is reported.
• Adapt ramp monitoring parameters in the safety
module.
• Adapt (quickstop) ramp parameters in the
application.
• Deactivate ramp monitoring in the safety module.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
111
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The safely limited increment is monitored in the "special
operation" operating mode. The increment
parameterised was exceeded.
• Adapt "SLI: Safely limited increment" parameter.
• Limit increments in the application.
• Deactivate monitoring of the safely limited
increment.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
128
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel A of output SD-Out1 cannot be deactivated.
Check wiring at the output SD-Out1 for short circuit.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
129
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Channel A of output SD-Out1 cannot be activated.
Check supply voltage and wiring for the safe output.