C15100 | s bus: configuration, C15101 | current dip switch display, C15111 | safety address – Lenze E94AYAE SM301 User Manual
Page 82: C15112 | effective safety address, C15111, C15101, C15112, C15100, 5parameter reference

5
Parameter reference
5.1
Parameter list | C15100
82
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C15100
C15101
C15111
C15112
Parameter | Name:
C15100 | S bus: Configuration
Data type: UNSIGNED_8
Index: 9475
d
= 2503
h
Configuration of the safe bus system.
Selection list
(Lenze setting printed in bold)
Info
0 No safety bus
1 PROFIsafe / PROFIBUS
2 PROFIsafe / PROFINET
From V1.1
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15101 | Current DIP switch display
Data type: UNSIGNED_16
Index: 9474
d
= 2502
h
Display of the DIP-switch setting (safety address) on the safety module.
Display range
(min. value | unit | max. value)
0
1023
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15111 | Safety address
Data type: UNSIGNED_16
Index: 9464
d
= 24F8
h
Safety address in the safety module.
Setting range
(min. value | unit | max. value)
Lenze setting
0
65534 0
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1
Parameter | Name:
C15112 | Effective safety address
Data type: UNSIGNED_16
Index: 9463
d
= 24F7
h
Effectively used safety address in the safety module.
Display range
(min. value | unit | max. value)
1
65534
Read access Write access CINH PLC-STOP No transfer Scaling factor: 1