Internal error - ais [0x012f0035, Internal error - aie [0x012f0036, 0x012f0032 – Lenze E94AYAE SM301 User Manual
Page 111: 0x012f0033, 0x012f0034, 0x012f0036, 0x012f0035, 6error messages
Lenze · SM301 safety module · Parameter setting & configuration · DMS 2.3 EN · 11/2013 · TD05
111
6
Error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Discrepancy error or functional test SD-In2 [0x012f0032]
Discrepancy error or functional test SD-In3 [0x012f0033]
Discrepancy error or functional test SD-In4 [0x012f0034]
Internal error - AIS [0x012f0035]
Internal error - AIE [0x012f0036]
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
50
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Signal error at two-channel safe input SD-In2.
• Check safe parameters for SD-In2.
• Check sensor at SD-In2.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
51
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Signal error at two-channel safe input SD-In3.
• Check safe parameters for SD-In3.
• Check sensor at SD-In3.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
52
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Signal error at two-channel safe input SD-In4.
• Check safe parameters for SD-In4.
• Check sensor at SD-In4.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
53
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Signal error at acknowledgement input AIS.
Replace safety module.
Module ID (decimal)
Error ID (decimal)
303: SM301 safety module
54
Response (Lenze setting printed in bold)
None System error Error Fault Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Signal error at acknowledgement input AIE.
Replace safety module.