Section 10

10-88

Model 3606 • Origin 10/99

27. With key in the START posi-

tion, engine does not crank.

1. Travel select lever is in forward (F)

or reverse (R).

1. Move the travel select lever to

NEUTRAL (N).

28. Engine runs momentarily

then stops.

Note: Refer to the Perkins or

Cummins engine trouble-
shooting information in
Section 8A or Section 8B.

1. Defective fuel run solenoid.

2. Fuel tank is empty.

3. Defective fuel injection pump.

4. Clogged or dirty fuel filter.

5. Excessive water in fuel.

1. Refer to Step 30, Fuel Run

Solenoid troubleshooting.

2. Fill fuel tank.

3. Check that pump operates

properly per the appropriate
engine section of this manual.

4. Replace fuel filter.

5. Drain water separator or replace

water filter.

29. NEUTRAL START SWITCH

Starter fails to crank engine
with travel select lever in
NEUTRAL (N), parking
brake switch engaged and
ignition key switch in
START position.

1. Check for problems in the

transmission shift switch or wiring.

2. Check transmission shift switch for

proper operation, continuity,
shorts, etc.

1. Check the transmission shift

switch wiring and fuse.

2. Replace a defective switch or

relay.

30. FUEL RUN SOLENOID

Ignition switch cranks
engine in START position
but engine doesn't operate
when key returns to RUN
position.

1. Fuel run solenoid.

2. Fuel tank is empty.

3. Defective injection pump.

1. Test for voltage at fuel run

solenoid with ignition key switch
in RUN position.

2. Fill fuel tank.

3. Replace pump. See the

appropriate engine
troubleshooting section.

31. PARKING BRAKE SWITCH

When switched to disen-
gaged position, park brake
switch fails to disengage
park brake.

1. Blown fuse.

2. Defective park brake solenoid.

3. Defective park brake switch.

4. Hydraulic problem.

1. Replace fuse.

2. Test solenoids and circuits; test

for continuity with park brake
switch in both positions; check
park brake solenoid operation.
Repair circuits or replace switch
and/or solenoids as required.

3. Replace.

4. Refer to Section 9 Hydraulic

System.

32. BACK-UP ALARM

Backup alarm doesn't
sound with travel select
lever in REVERSE (R).

1. No voltage at backup alarm;

broken wiring or blown fuse.

2. Defective alarm.

3. Defective travel select lever.

1. Test alarm and ground circuit;

check for voltage at alarm. Repair
wiring or replace fuse as
required.

2. Test alarm and ground circuit.

3. Test travel select lever for

continuity and circuit for shorts.
Replace travel select lever if
defective.

Electrical System Troubleshooting

Problem

Possible Cause

Remedy