Hydraulic System

9-123

31. Directional control valve

difficult to shift.

1. Broken internal parts.

2. Scored valve body bore,

producing leakage between
spool and body.

3. Broken centering spring.

1. Disassemble control valve and

replace broken parts.

2. Inspect bore. Replace valve

section if scored.

3. Replace spring.

32. Movement of joystick fails

to cause spool in control
valve to shift.

1. Faulty joystick, joystick switch,

wiring, or solenoid valve.

2. Insufficient pressure to move

spool.

3. Check main control valve for

stuck spool.

1. Troubleshoot and repair as

required. Refer to Section 10
Electrical System
.

2. Check pilot pressure.

3. Replace as required.

Hydraulic System Troubleshooting

Problem

Cause

Remedy