24

The software immediately begins to download onto the switch.
The Xmodem File Send window in Figure 7 displays current status
of the software download. The download process take a couple
minutes to complete.

Figure 7 XModem File Send Window

Once the download process is completed, the following prompt is
displayed:

XMODEM transfer has successfully completed.
Now writing to Flash PROM.

Please wait for FLASH writes to complete.

This may take up to 1 minute.

Do not reset, do not remove power.

The system will automatically reboot.

When the image file is downloaded to all the modules in the stack,
make sure to set the terminal speed back to the default of 9600 by
performing the following steps:

17. From the local management interface menu, select Disconnect from

the Call menu or click the Disconnect icon

.

18. From the local management interface menu bar, select Properties

from the File menu or click the Properties icon

. The AT-S25

Properties window in Figure 3 on page page -22 is displayed.

19. Click the Configure button. The Properties window of the connecting

COM in Figure 4 is displayed.

20. Click the Restore Defaults button, the Bits per second field is

displayed with 9600 as its setting; and click OK.

The system is now rebooted and you are returned to the AT-S25
management software login menu.