Page 73

background image

3.11

Setting the Remote Copy Transport Layer

InForm OS Version 2.3.1

Remote Copy User’s Guide

This command performs a ping from the specified interface (

) to the specified IP

address on the target system (

). Issue this command twice (once for each

interface), for each system in the configuration.

If the

controlport rcip ping

command does not work:

Verify that the GigE cards are all in the

ready

state using the

showport -rc

command.

Verify all IP addresses, netmasks, gateways, and physical connections.

Use

controlport rcip ping

to test connectivity between both IP interfaces on

both systems.

Verify the MTU settings are correct. See

Increasing MTU (Optional)

on page 3.11 for

more information.

Verify the

controlport rcip speed

settings. See

controlport

on page B.9 for

details.

If the pings do not succeed, seek help from a Network Administrator.

3.4.2.3 Increasing MTU (Optional)

Depending on the network setup, you might be able to increase the maximum transmission

unit (MTU) size of the GigE interfaces to increase throughput between storage servers. The

throughput and CPU utilization of GigE adapters can be improved if the adapters are

configured to use jumbo frames (9000-bytes frames) rather than the default 1500-byte frames.

When supported by the network, use an MTU value of 9000. However, note that this setting

requires that the IP network support jumbo frames end-to-end (along the entire path between

the two storage servers).

NOTE: Because of the spanning tree and MAC address learning, you might need

to ping each server several times before all tables are updated and the ping

succeeds.

CAUTION: Do not proceed with the rest of the Remote Copy setup until pings

succeed between the GigE ports in the two storage servers.