beautypg.com

B.17 – HP 3PAR Remote Copy Software User Manual

Page 153

background image

B.17

controlport

InForm OS Version 2.3.1

Remote Copy User’s Guide

If there are active hosts or physical disks when issuing the

controlport rst

or

offline

commands, a warning is returned and you are prompted for confirmation to complete the

execution of the commands.

When issuing the

controlport ct

,

cl2

,

rate

, or

rscn

commands, if there are active

disks on the port, an error is returned. If there are active hosts on the port, the

-f

option is

overridden (if specified), a warning is returned, and you are prompted for confirmation to

complete the execution of the commands.

The

controlport rcip addr

command is only allowed for node/slot/port combinations

where there is an interface installed.

controlport config

mode changes are not allowed when ports are online.

The

ct

,

cl2

, or

rate

subcommands automatically reset the port for the changes to take

effect.

Issue the

showport

command with either the

-i

or

-par

options to verify the success of

the

controlport

command.

Resetting a port causes a momentary dip in throughput, but no loss of connectivity.

Use caution when changing modes for ports in LSI Fibre Channel adapters. Changing the

mode of one port in a pair (for example, from initiator to target) causes the other port in

the pair to also undergo a mode change. In the case where one port in the pair is offline

(and therefore a mode change can be allowed), but the partner port is online, changing

the mode of the offline port causes the online partner port to undergo mode change as

well. This results in loss of use of the partner port because it is no longer online.

Issuing the

controlport rst -l

command affects both ports of a port pair. Only use this

command when irreversible damage has been done to a port or port pair.