B.72 – HP 3PAR Remote Copy Software User Manual
Page 208

B.72
statport
Remote Copy User’s Guide
InForm OS Version 2.3.1
Specifies the minimum threshold using any integer. The integer can be optionally
followed with
k
or
K
to indicate a multiple of 1000,
m
or
M
to indicate a multiple of
1000000, or
g
or
G
to indicate a multiple of 1000000000.
An example of this option in use is
–filt curs,r,iops,10k
that indicates that statistics
for a device that has more than 10,000 current read-only I/O operations are displayed.
–ni
Shows only nonidle devices. This option is shorthand for the option
–filt
curs,t,iops,0
.
SPECIFIERS
None.
RESTRICTIONS
The
–filt
option applies to data transfers only.
EXAMPLE
The following example displays one iteration of I/O statistics for all ports:
The columns in the example above are identified as follows:
■
Port
. The port ID.
■
D/C
. The
Data
or
Control
transfers.
■
r/w
. The I/O type. Values can be read (
r
), write (
w
), or read and write (
t
).
cli% statport -iter 1
11:32:25 06/01/07 r/w I/O per second KBytes per sec Svt ms IOSz KB
Port D/C Cur Avg Max Cur Avg Max Cur Avg Cur Avg Qlen
0:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:2:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:2:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
0:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
1:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0
------------------------------------------------------------------------
total Data t 0 0 0 0 0.0 0.0 0.0 0.0 0