beautypg.com

B.72 – HP 3PAR Remote Copy Software User Manual

Page 208

background image

B.72

statport

Remote Copy User’s Guide

InForm OS Version 2.3.1

Specifies the minimum threshold using any integer. The integer can be optionally

followed with

k

or

K

to indicate a multiple of 1000,

m

or

M

to indicate a multiple of

1000000, or

g

or

G

to indicate a multiple of 1000000000.

An example of this option in use is

–filt curs,r,iops,10k

that indicates that statistics

for a device that has more than 10,000 current read-only I/O operations are displayed.

–ni

Shows only nonidle devices. This option is shorthand for the option

–filt

curs,t,iops,0

.

SPECIFIERS

None.

RESTRICTIONS

The

–filt

option applies to data transfers only.

EXAMPLE

The following example displays one iteration of I/O statistics for all ports:

The columns in the example above are identified as follows:

Port

. The port ID.

D/C

. The

Data

or

Control

transfers.

r/w

. The I/O type. Values can be read (

r

), write (

w

), or read and write (

t

).

cli% statport -iter 1

11:32:25 06/01/07 r/w I/O per second KBytes per sec Svt ms IOSz KB

Port D/C Cur Avg Max Cur Avg Max Cur Avg Cur Avg Qlen

0:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:2:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:2:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

------------------------------------------------------------------------

total Data t 0 0 0 0 0.0 0.0 0.0 0.0 0