beautypg.com

10 stopping remote copy, 11 remote copy commands, Stopping remote copy – HP 3PAR Remote Copy Software User Manual

Page 117: Remote copy commands

background image

4.11

Stopping Remote Copy

InForm OS Version 2.3.1

Remote Copy User’s Guide

4.10 Stopping Remote Copy

`

If you want to stop using Remote Copy, issue the

stoprcopy

command as follows:

`

To stop using Remote Copy functionality on all volume groups, delete all Remote Copy

configuration data, and release all resources used by Remote Copy, add the

-clear

option

to the

stoprcopy

command as follows:

Without the

-clear

argument, this command only stops the Remote Copy. You can restart

that copy later using the

startrcopy

command.

4.11 Remote Copy Commands

Table 4-2

contains a list of tasks and their associated commands. Enter Remote Copy

commands using the InForm CLI. Refer to the InForm OS Command Line Interface Reference

for detailed instructions on using the CLI. For details about each command, refer to

Appendix B, Remote Copy Commands

.

# stoprcopy -stopgroups

# stoprcopy -stopgroups -clear

NOTE: See

Remote Copy and Thin Provisioning

on page 2.33 for important

information about space allocation and deleted snapshots.

NOTE: When issuing commands that are mirrored from one system to the other,

there is a five minute timeout limit. After five minutes, if the other system does

not respond to a command, the following error message appears:

target system could not be contacted