B.24
dismissrcopylink
Remote Copy User’s Guide
InForm OS Version 2.3.1
Specifies the node, slot, and port of the Ethernet port on the local system and an IP address
of the peer port on the target system. This specifier can be repeated.
Specifies the node, slot, and port of the Fibre Channel adaptor port on the primary system
and a World Wide Name (WWN) of the peer port on the target system. This specifier can be
repeated.
RESTRICTIONS
■
This command requires a 3PAR Remote Copy license. Contact your local service provider for
further information.
■
This command should only be used to remove sending links. See
page 2.17 for details on sending and receiving links.
■
This command cannot be used to remove the last link of a target system with started
groups.
EXAMPLES
The following example removes the link from the Ethernet port located at
2:2:2
of
System 2:
NOTES
■
This command is finished with a list of one or more links to be dismissed.
■
For IP targets, this list is made up of pairs composed of the node containing the Ethernet
port on the primary system and an IP address on the backup system.
■
For Fibre Channel targets, this list is made up of sets with the node, slot, and port of the
Fibre Channel adaptor port on the primary system and a WWN address on the backup
system.
cli% dismissrcopylink System2 2:2:2:193.1.2.11