beautypg.com

B.24 – HP 3PAR Remote Copy Software User Manual

Page 160

background image

B.24

dismissrcopylink

Remote Copy User’s Guide

InForm OS Version 2.3.1

...

Specifies the node, slot, and port of the Ethernet port on the local system and an IP address

of the peer port on the target system. This specifier can be repeated.

...

Specifies the node, slot, and port of the Fibre Channel adaptor port on the primary system

and a World Wide Name (WWN) of the peer port on the target system. This specifier can be

repeated.

RESTRICTIONS

This command requires a 3PAR Remote Copy license. Contact your local service provider for

further information.

This command should only be used to remove sending links. See

Remote Copy Links

on

page 2.17 for details on sending and receiving links.

This command cannot be used to remove the last link of a target system with started

groups.

EXAMPLES

The following example removes the link from the Ethernet port located at

2:2:2

of

System 2:

NOTES

This command is finished with a list of one or more links to be dismissed.

For IP targets, this list is made up of pairs composed of the node containing the Ethernet

port on the primary system and an IP address on the backup system.

For Fibre Channel targets, this list is made up of sets with the node, slot, and port of the

Fibre Channel adaptor port on the primary system and a WWN address on the backup

system.

cli% dismissrcopylink System2 2:2:2:193.1.2.11