setrcopytarget

InForm OS Version 2.3.1

Remote Copy User’s Guide

The measured bandwidth of the connection to the target, specified in kilobytes (kB) per

second. This specifier can only be used with the

tunelinks

subcommand.

The measured round-trip latency of the connection to the target, specified in milliseconds

(ms). This specifier can only be used with the

tunelinks

subcommand.

RESTRICTIONS

This command requires the 3PAR Remote Copy license. Contact your local service provider

for further information.

If the

mirror_config

policy is set and the

setrcopytarget

command is issued with the

pol

subcommand, the duplicated configuration commands cannot be issued on the

secondary. Doing so results in an error.

The

name

and

tput

subcommands cannot be used on a target with started groups.

There must be an active connection between the systems in the Remote Copy pair in order

to issue commands on the primary server to be mirrored to the backup server. If there is no

connection, the commands will return an error.

EXAMPLES

The following example turns off configuration mirroring from

InServ1

to

InServ2

, where

InServ2_out

is a secondary target on

InServ1

that points at

InServ2

:

NOTES

The

setrcopytarget

command requires the groups associated with it be stopped prior to

using the following options:

setrcopytarget name

setrcopytarget tput

The

setrcopytarget

command with the following arguments can be run without

bringing down its Remote Copy groups:

setrcopytarget pol

On InServ1:

cli% setrcopytarget pol no_mirror_config InServ2_out