beautypg.com

Bulletin f-107-uxf3 – Dwyer UXF3 User Manual

Page 84

background image

-76-

4.11.7. How to validate a serial transmission (RS-232C/RS-485)

Description
z Validates a transmission before using the transmission function.

Setting content

Transmission type, transmission rate, parity, stop bits and slave No.

Settable range

Transmission type

: RS-232C (factory set) or RS-485.

Transmission rate (BAUD RATE) : 2400 BPS, 4800 BPS, 9600 BPS (factory set), 19200 BPS, or 38400 BPS.
Parity

: NONE, EVEN (factory set), ODD

Stop bits

: 1 BIT (factory set), 2 BITS

Station No.

: 1 to 31 (factory set: 1)

Communication protocol

: MODBUS RTU mode (factory set)

N

.

For actual keying, refer to the typical operation indicated below. Set the parameter protection to OFF beforehand. (See Section 4.4.1.)

Operation
(example)

Select the RS-485, and set the baud rate to 9600 BPS, the parity to "NONE", the stop bits to "1 BIT", and the slave
No. to "5".

Key operation

Description

Display

ź

Press the

key 4 times to display “MAINTENANCE MODE”.

MAINTENANCE MODE

ENT

ź

Press the

ENT

key once to display “RAS INFORMATION”.

RAS INFORMATION
0000000000000000

ź

Press the

key 7 times to display “COMMUNICATION”.

COMMUNICATION

ENT

ź

Press the

ENT

key once to select, and press it once again to blink on the

2nd line.

MODE

RS-232C

ź

Press the

key once to display “RS-485”.

MODE

RS-485

Press the

ENT

key once to register.

MODE

COMPLETE

Ļ

ENT

ź
ź
ź
ź

ʊʊʊ RS-485 has been registered. ʊʊʊ

MODE

RS-485

ź

Press the

key once to display “BAUD RATE”.

Because “9600 BPS” is set, go to the next step.

To select other baud rate, press the

ENT

key, and select by the

key,

and register by the

ENT

key.

BAUD RATE

9600BPS

ź

Press the

key once to display “PARITY”.

PARITY

ODD

ENT

ź

Press the

ENT

key once to blink on the 2nd line.

PARITY

ODD

ź

Press the

key once to display “NONE”.

PARITY

NONE

Press the

ENT

key once to register.

PARITY

COMPLETE

Ļ

ENT

ź
ź
ź
ź

ʊʊʊ “NONE” has been registered. ʊʊʊ

PARITY

ODD

ź

Press the

key once to display “STOP BIT”.

Because “1 BIT” is set, go to the next step. To select “2 BITS”, press the

ENT

key, and select by the

key, and register by the

ENT

key.

STOP BIT

1 BIT

ź

Press the

key once to display “STATION No.”.

STATION NO.

01

Bulletin F-107-UXF3