4.9.2.2. Setting the preset value
Description
z Preset value: Value which appears on the total counter when the total value has been reset.
Settable range:0 to 99999999
Set the total unit beforehand in the MEASURE SETUP mode. (Refer to 4.8.3.)
When setting, stop status is set at the total mode.
Total value
Preset value
Time
Reset
Reset
Reset
For actual keying, refer to the typical operation indicated below. Set the parameter protection to OFF beforehand. (See Section 4.4.1.)
Operation
(example)
Set the preset value to 100m
3
.
* Set the total unit beforehand.
Key operation
Description
Display
ź
Press the
key twice to display “OUTPUT SETTING”.
OUTPUT SETTING
ENT
ź
Press the
ENT
key once to display “ZERO ADJUSTMENT”.
ZERO ADJUSTMENT
SET ZERO
ź
Press the
key 5 times to display “TOTAL”.
TOTAL
ENT
ź
Press the
ENT
key once to display “TOTAL MODE”.
TOTAL MODE
STOP
ź
Press the
key twice to display “TOTAL PRESET”.
TOTAL PRESET
0 m3
ENT
ź
Press the
ENT
key once to display the cursor.
TOTAL PRESET
0
0000000 m3
ź
Press the
key 6 times to move the cursor.
* Note that, it cannot be entered on the first digit (leftmost).
TOTAL PRESET
00000
0
00 m3
ź
Press the
key once to display “1”.
TOTAL PRESET
00000
1
00 m3
Press the
ENT
key once to register.
TOTAL PRESET
COMPLETE
Ļ
ENT
ź
ź
ź
ź
ʊʊʊ “TOTAL PRESET” has been registered. ʊʊʊ
TOTAL PRESET
100 m3
ź
Press the
key 4 times to display “TOTAL MODE”.
TOTAL MODE
STOP
ENT
ź
Press the
ENT
key once to blink the cursor.
TOTAL MODE
STOP
ź
Press the
key once, and select “TOTAL PRESET”.
TOTAL MODE
TOTAL PRESET
Press the
ENT
key once to register.
TOTAL MODE
COMPLETE
Ļ
ENT
ź
ź
ź
ź
ʊʊʊ “TOTAL MODE” has been registered. ʊʊʊ
TOTAL MODE
TOTAL PRESET
ESC
Press the
ESC
key twice and then press the
key 3 times to enter
the measurement mode.
0.000 %
0.000 m3/h