Setting of unit, How to set the unit system, Bulletin f-107-uxf3 – Dwyer UXF3 User Manual
Page 41
-33-
4.8. Setting of unit
4.8.1. How to set the unit system
Description
z Measurement unit can be selected from metric or inch system.
z Metric system (factory set)
Length············································· mm, inch
Flow velocity ··································· m/s, ft/s
Flow rate ········································· L/s, L/min, L/h, L/d, kL/d, ML/d, m
3
/s, m
3
/min, m
3
/h, m
3
/d, km
3
/d, Mm
3
/d, metric barrels (BBL units)
gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d, ft /s, ft /min, ft /d, kft /d, Mft /d, barrels (BBL units)
Total unit ········································· mL, L, m
3
, km
3
, Mm
3
, gal, kgal, ft , kft , Mft , Acre-ft, mBBL, BBL, kBBL
Kinematic viscosity coefficient ········ E
-6
m
2
/s, E ft /s
For actual keying, refer to the typical operation indicated below. Set the parameter protection to OFF beforehand. (See Section 4.4.1.)
Operation
(example)
Change the unit system from inch system to metric system.
Key operation
Description
Display
ź
Press the
key 3 times to display “MEASURE SETUP”.
MEASURE SETUP
ENT
ź
Press the
ENT
key once to display “SYSTEM UNIT”.
SYSTEM UNIT
INCH
ENT
ź
Press the
ENT
key once to blink the cursor.
SYSTEM UNIT
INCH
ź
Press the
key once to display “METRIC”.
SYSTEM UNIT
METRIC
Press the
ENT
key once to register.
SYSTEM UNIT
COMPLETE
Ļ
ENT
ź
ź
ź
ź
ʊʊʊ METRIC has been registered. ʊʊʊ
SYSTEM UNIT
METRIC
ESC
Press the
ESC
key once and
key twice to return to the measurement
mode.
0.000 %
0.000 m3/h
Bulletin F-107-UXF3
3
3
3
3
3
3
3
3
2