Chapter 24 Troubleshooting

MES-2110 User’s Guide

209

I cannot see or access the Login screen in the Web Configurator.

1

Make sure you are using the correct IP address.

• The default IP address is

192.168.1.1

.

• If you changed the IP address, use the new IP address.
• If you changed the IP address and have forgotten it, see the troubleshooting

suggestions for

I forgot the IP address for the MES-2110.

2

Check the hardware connections, and make sure the LEDs are behaving as
expected. See

Section 3.4 on page 35

.

3

Make sure your Internet browser does not block pop-up windows and has
JavaScripts and Java enabled.

4

Make sure your computer is in the same subnet as the MES-2110. (If you know
that there are routers between your computer and the MES-2110, skip this step.)

5

Reset the device to its factory defaults, and try to access the MES-2110 with the
default IP address. See

Section 5.6 on page 59

.

6

If the problem continues, contact the vendor, or try one of the advanced
suggestions.

Advanced Suggestions

Try to access the MES-2110 using another service, such as Telnet or over the
console port. If you can access the MES-2110, check the remote management
settings to find out why the MES-2110 does not respond to HTTP.

Some possible reasons for being unable to connect over the in-band management
ports are that you:

1

Deleted the management VLAN (default is VLAN 1).

2

Deleted all port-based VLANs with the CPU port as a member. The “CPU port” is
the management port of the MES-2110.

3

Filtered all traffic to the CPU port.

4

Disabled all ports.

5

Misconfigured the text configuration file.

6

Prevented all services from accessing the MES-2110.