Nortel Networks 1000E User Manual
Page 55
System components
Page 55 of 466
Communication Server 1000E
Installation and Commissioning
For detailed information about the ISP1100 Signaling Server, refer to
Signaling Server: Installation and Commissioning (NN43001-312).
Connectors
(front)
•
The DB-9 serial port, the CD-ROM and floppy
drives are located on the unit’s faceplate.
•
The DB-9 serial port can support a login session
for Command Line Interface (CLI) management.
•
See Figure 6 on
.
Connectors
(rear)
•
The TLAN network interface (P2) connects the
unit to a TLAN network interface on a Layer 2
Switch.
•
The ELAN network interface (P1) connects the
unit to an ELAN network interface on a Layer 2
Switch.
•
The DB-9 serial port can support a login session
for Command Line Interface (CLI) management.
•
There are three ports not used for any CS 1000E
system function. Do not plug any device into these
ports.
•
See Figure 7 on
.
CAUTION — Service Interruption
Do not connect maintenance terminals or modems to
the faceplate and I/O panel DB-9 male serial
maintenance port at the same time.
Table 2
ISP1100 Signaling Server profile (Part 3 of 3)
Property
Description