Connecting a trunk, Procedure 66 connecting a trunk – Nortel Networks 1000E User Manual
Page 292
Page 292 of 466
Installing and cross-connecting a trunk card
NN43041-310
Standard 01.11
October 2008
•
NTRB21 TMDI 1.5 Mbit DTI/PRI
•
NT6D70 SILC
•
NT6D71 UILC
Note: Now NT6D70 SILC and NT6D71 UILC Digital trunk cards can
be installed in slots 7 to 10 in a Media Gateway Expander.
For additional information about installing Digital trunk cards, refer to the
following documents:
•
ISDN Primary Rate Interface: Installation and Configuration
(NN43001-301)
•
ISDN Basic Rate Interface: Installation and Configuration
(NN43001-318)
•
ISDN Primary Rate Interface: Maintenance (NN43001-717)
•
ISDN Basic Rate Interface: Maintenance (NN43001-718)
Connecting a trunk
Follow Procedure 66 to connect a trunk.
Procedure 66
Connecting a trunk
1
From the assignment record, determine the location of the trunk
connection and its associated Terminal Number (TN) at the
cross-connect terminal.
2
With cross-connect wire, connect the trunk to the TN.
Make sure that the wiring is not reversed and that it is on the correct
terminals.
•
list the connections
for trunks.
•
For European trunk connections, see Table 27 on
to
•
For UK trunk connections, see Table 36 on
to Table 42 on