Universal trunk card connections, Table 24 on – Nortel Networks 1000E User Manual
Page 293
![background image](/manuals/194031/293/background.png)
Installing and cross-connecting a trunk card
Page 293 of 466
Communication Server 1000E
Installation and Commissioning
Note: See “Installing and cross-connecting a Power Fail Transfer Unit”
on
for connecting trunks with the PFTU.
End of Procedure
Universal Trunk card connections
The Universal Trunk card (NT8D14) provides eight Analog trunks that can
function in the modes identified in Table 24. Refer to Table 25 on
for the connections to the Universal trunk at the cross-connect terminal.
Table 24
NT8D14 Universal Trunk card – modes and option settings
Modes
Location
Jumper strap
Central (CO)
J1, J2
OFF
2-way TIE trunk (loop Dial Repeat)
J1, J2
OFF
2-way TIE trunk (Outgoing Incoming
Dial)
J1, J2
OFF
Recorded Announcement (RAN)
J1, J2
OFF
Paging trunk
J1, J2
OFF
Japan CO/DID operation
J1, J2
OFF
DID operation
Loop length>2000 ohms
J1, J2
ON
DID operation
Loop length <2000 ohms
J1, J2
OFF
Note 1: OFF indicates that no strap is present.
Note 2: J1 and J2 locations apply to all eight trunks.