Connecting an MRV LX8020S-102AC-R Terminal Server

NN43041-310

Standard 01.11

October 2008

Follow Procedure 62 to establish access to a Call Server from a PC through
telnet Terminal Server. Use the same port number for each procedure step.

Procedure 62
Accessing a CS 1000E from a PC through telnet Terminal Server

1

Connect to the management port or virtual management port as shown in
Procedure 61 on

page 271

or Procedure 59 on

page 269

.

2

Define the port baud rate to equal the baud rate of the CS 1000E COM
port. Enter:

InReach:0 >>config port async speed

InReach:0 >>config port async 1 speed 9600

Where: xx = Port number from 1-20 and BAUDRATE = the baudrate of
the connected Call Server com port.

3

To avoid autohangup:

InReach:0 >>config port async no autohangup

InReach:0 >>config port async 1 no autohangup

4

Turn off authentication.Then save the configuration and check it:

InReach:0 >> config port async no authentication

outbound

InReach:0 >>save config flash

InReach:0 >>show port async chara

InReach:0 >> config port async 1 no authentication

outbound

InReach:0 >>save config flash

InReach:0 >>show port async 1 chara

5

Run telnet on the PC.

a.

In Windows:

Start > Run

b.

Enter the Input telnet command.

TELNET xxx.xx.x.xx xxxx

Where: