background image

Connecting an MRV LX8020S-102AC-R Terminal Server

Page 273 of 466

Communication Server 1000E

Installation and Commissioning

xxx.xx.x.xx = Terminal Server IP Address

xxxx = telnet port (for port 1 to 20)

Note: The value of the target telnet port, xxxx, is determined using the
following formula:

TELNET PORT = 2 000 + (port number xx × 100)

For example, if the telnet port is 1, then:

TELNET PORT = 2 000 + (1 x 100)

= 2 000 + (100)
= = 2100

If the Terminal Server IP Address is 47.11.244.101 and the telnet port is
1, then TELNET command line is:

telnet 47.11.244.101 2100

Example:

telnet 47.11.244.101 (telnet to virtual management port)

End of Procedure

Configuring an rlogin port for various applications

The CS 1000E system uses Pseudo TTY (PTY) ports as TTY ports. All serial
applications, such as CDR and Traffic, can be implemented through PTY
ports. PTY ports are configured in LD 17. An external device, such as a
printer, can access a Call Server PTY port through the Terminal Server by
using a remote login (rlogin) session. Using

HyperTerminal,

follow

Procedure 63 to configure a transparent rlogin port.

Procedure 63
Configuring an rlogin port for various applications

1

Enable TCP keep alive timer.

TCP Keepalive feature allows to change polling intervals, number
retries, etc.The TCP keep alive timer is mainly required to check if the
link is up.

This procedure explains how to modify the sysctl.conf file, which
contains the TCP Keepalive settings.

2

To modify the sysctl.conf file: