The TTY Settings are:

Baud Rate: 9600

Data bit: 8

Stop bit: 1

Parity: None

Flow Control: None

CP PM Call Server Switch Settings

The CP PM Call Server switch S5 must be set to position 1 to indicate that a
CF card is used for the FMD.

The CP-PM Signaling Server switch S5 must be set to position 2 to indicate
that a hard disk is used for the FMD.

CP PM Call Server software

The CP PM Call Server software features the following enhancements for
CS 1000 Release 5.0:

software is large-system based

uses the same machine type (711) as CP PII and CP PIV

new system type (4021)

new High Availability package (410)

new menus for setting the Side, Loop and Shelf information. The Loop
and Shelf refer to the IPMG Loop and Shelf where the CP PM CS is
located.