10base2 ethernet, End of segment – Intermec 6710 User Manual
Page 55
SECTION 3
"
Installation
6710 Access Point User’s Guide 3-11
10BASE2 Ethernet
The access point connects to the end or middle of the
10BASE2 cable segment.
" NOTE:
Cable lengths between network devices on the 10BASE2 Ethernet
LAN must meet ANSI/IEEE standards.
End of Segment
See Figure 3-7 and the procedure following it.
1. Cable terminator (50 ohm)
2. T-connector
3. 10BASE2 cable
3
1
2
Figure 3-7
End of 10BASE2 Segment
10 BASE 2
10 BASE T
AC INPUT
100/240 VAC
AUI
DIAG
1. Plug the T-connector (2) into the 10 BASE 2 port.
2. Plug one end of the Ethernet cable (3) into an open
end of the T-connector. Align the notches in the cable
end with the posts on the T-connector, push the cable
in, and twist one-quarter turn.
3. Plug the cable terminator (1) into the other end of the
T-connector.