Exiting the ROM Command Monitor
Exit the command monitor by running the Reboot command
(B) or Run Flash Boot File command (FR) on the ROM
command monitor’s Main Menu.
Software Download Example
The FLASH program for the access point is called
USTART29.BIN. A simple method for upgrading an access
point with new FLASH is to set one up as a TFTP server
and then download new FLASH into another access point
(the client). This method is “simple” because you can easily
configure an access point as a TFTP server.
The general procedure is as follows:
1. Upgrade one access point with a new version of
FLASH through the DIAG port.
2. Enable the upgraded access point as a TFTP server.
3. Use Telnet and TFTP to upgrade another access point
(client).
This procedure may also download new HTML and GIF
files, which enable you to configure the access point through
a Web browser.
Upgrading Through DIAG Port
The following pages show an example of how to upgrade an
access point through its DIAG port. This unit will become
the TFTP server. The example assumes that: