Intermec 6710 User Manual
Page 192
SECTION 5
"
Software Download
5-32
6710 Access Point User’s Guide
Command
Description
File>tftp get 1.2.3.4 falcon_d.29k id: Copy self-extracting data file
FALCON_D.29K from the server
to the client’s inactive data seg-
ment.
File>fb ib: id:
Make the client’s inactive boot and
data segments the active seg-
ments.
File>fd
Display the FLASH file directory
to verify that the boot and data
segments are the active segments.
File>exit
Exit the File Menu and return to
the Main Menu.
>reboot
Run the new FLASH file by re-
starting the access point. Note
that when you reboot the access
point client, the Telnet connection
is lost. Wait about 30 seconds for
the unit to start up again before
trying to establish another Telnet
connection.
File>fd
Display the FLASH file directory
to verify that the correct files are
in the active segment.
4. Repeat the above commands for each access point
client that needs a new version of FLASH.
5. After you have upgraded all access point clients, stop
the TFTP server process in the access point you used
as the server by typing:
File>
tftp server stop