Intermec 6710 User Manual
Page 310

APPENDIX G
"
MIB
G-60
6710 Access Point User’s Guide
rtIsChild
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”True if the destination is a child node”
::= { rtEntry 13 }
rtIsAp
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”True if the destination is an AP”
::= { rtEntry 14 }
rtIsDistributed
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”True if the path is through a distributed AP
(root node only)”
::= { rtEntry 15 }
rtIsRemoteLan
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”True if the destination is a remote LAN”
::= { rtEntry 16 }
rtNS
OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
”MAC-R send sequence number for terminal nodes.
The
16-bit (0-65535) sequence number of the last OWL data
request PDU sent to the destination”
::= { rtEntry 17 }