Cable type, Static addresses – Intermec 6710 User Manual
Page 108
SECTION 4
"
Configuration
4-42
6710 Access Point User’s Guide
Cable Type
Cable Type specifies the type of Ethernet medium to which
the access point is connected. It is recommended that you
explicitly set the cable type. Settings are:
10BaseT
10Base2
AUI
Auto Detect
Setting
Description
10BaseT
Selects the RJ11 connector (sets type to
10BASE-T, twisted pair). The cable type
defaults to 10BASE-T if no traffic is heard on
any Ethernet port (10BASE2, 10BASE5, or
10BASE-T) during a 10-second time window
when the access point starts up.
10Base2
Selects the BNC connector (sets type to
10BASE2, thinnet).
AUI
Selects the AUI 15-pin D-sub connector (sets
type to 10BASE5 thicknet, and other types).
Auto Detect
(default)
Automatically selects the correct cable type by
listening for traffic on the Ethernet ports during
initialization. For this to work, the access point
must be connected to the Ethernet medium
during system start-up, and another device on
the Ethernet medium must be transmitting at
least one frame every 10 seconds.
[Static Addresses]
Use [Static Addresses] to define a list of 20 or fewer
permanent unicast 802 MAC addresses connected to this
Ethernet port. The Static Address Table displays the
addresses: