Intermec 6710 User Manual
Page 190

SECTION 5
"
Software Download
5-30
6710 Access Point User’s Guide
"
You have established a connection between a PC and
the access point’s DIAG port, and have accessed the
ROM command monitor.
"
An old version of FLASH is in segment 1.
"
The new version of FLASH is going into segment 1.
"
Segment 2 is the active boot segment.
1. When the access point has entered the ROM command
monitor, type the following commands to upgrade the
unit.
Command
Description
ap>pwd
Enter the password menu.
Enter the password.
The default password is
CR52401OWL (must be upper-
case).
passwd>fe 1
Erase FLASH segment 1.
passwd>x
Exit the password menu.
ap>fx 1
Download the new FLASH file into
segment 1.
passwd>fb 1
Change the boot segment number
from 2 (in this example, the active
boot segment) to 1.
ap>fr
Run the new FLASH boot file by
restarting the access point.
2. After the access point reboots and is running in
FLASH mode, use the Fd command to display the file
directory and verify that the new version of FLASH is
in segment 1.
3. Ensure that this access point has a valid IP address.
Change the address if necessary and remember what
it is. You need the IP address to configure TFTP
clients in other access points.