Intermec 6710 User Manual
Page 274
APPENDIX G
"
MIB
G-24
6710 Access Point User’s Guide
-- ******************************************************************
-- *
-- *
6710MIB.MIB Version 1.32
-- *
-- ******************************************************************
OWL DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Counter, Gauge, TimeTicks
FROM RFC1155-SMI
PhysAddress, DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
--
This MIB module uses the extended OBJECT-TYPE macro as
--
defined in RFC-1212;
norand
OBJECT IDENTIFIER ::= { enterprises 469 }
manage
OBJECT IDENTIFIER ::= { norand 1000 }
products
OBJECT IDENTIFIER ::= { manage 1 }
ap6710
OBJECT IDENTIFIER ::= { products 1 }
gw4030
OBJECT IDENTIFIER ::= { products 2 }
wnas
OBJECT IDENTIFIER ::= { products 3 }
ts6950
OBJECT IDENTIFIER ::= { products 4 }
gwap6910
OBJECT IDENTIFIER ::= { products 5 }
uap2100
OBJECT IDENTIFIER ::= { products 6 }
msd6710
OBJECT IDENTIFIER ::= { products 7 }
norandNET
OBJECT IDENTIFIER ::= { manage 2 }
nSystem
OBJECT IDENTIFIER ::= { norandNET 1 }
hw
OBJECT IDENTIFIER ::= { nSystem 1 }
-- The Hardware Parameters Group
hwPartNo
OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
”The Norand part number of the hardware device.”
::= { hw 1 }
hwDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
”The description of the hardware device.”
::= { hw 2 }