Intermec 6710 User Manual
Page 315
APPENDIX G
"
MIB
6710 Access Point User’s Guide G-65
bsAddress
OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
”802 address of the AP”
::= { brgState 3 }
bsLanId
OBJECT-TYPE
SYNTAX INTEGER (0..254)
ACCESS read-only
STATUS mandatory
DESCRIPTION
”OWL LAN ID (0-254)”
::= { brgState 4 }
bsCostToRoot
OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
”Path cost to the root”
::= { brgState 5 }
bsIsRoot
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”TRUE, if the AP is the root”
::= { brgState 6 }
bsIsAttached
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”TRUE, if the AP is attached”
::= { brgState 7 }
bsAttachId
OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
”16-bit (0-65535) ATTACH sequence number.
This
number is incremented each time the AP sends an
ATTACH request.”
::= { brgState 8 }