Intermec 6710 User Manual
Page 281

APPENDIX G
"
MIB
6710 Access Point User’s Guide G-31
ceEnabled
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
”A value of true(1) signifies that the critical
error log was successfully initialized as part
of the power-up sequence.
Any errors in that
initialization process result in a value of
false(2).”
::= { criticalErrors 1 }
ceOverflow
OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
”Overflow error code.
If the overflow code is
non-zero, it indicates that the log has
overflowed and the overflow code contains the
last displaced value.”
::= { criticalErrors 2 }
ceReset
OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
”A user can reset the critical error log by
setting ceReset to true(1).
Valid values are
true(1) or false(2).”
::= { criticalErrors 3 }
ceLogTable
OBJECT-TYPE
SYNTAX SEQUENCE OF CELogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
”Critical Error Log Table”
::= { criticalErrors 4 }
ceLogEntry
OBJECT-TYPE
SYNTAX CELogEntry
ACCESS not-accessible
STATUS mandatory
INDEX { ceLogErrorCode }
::= { ceLogTable 1 }