Electronic gear setting examples, Ball screws – Yaskawa FSP Amplifier User Manual
Page 94

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-27
5. Set the parameters.
Reduce the electronic gear ratio to lower terms so that both A and B are
integers smaller than 65535, then set A and B in the respective
parameters:
Pn202
Electronic Gear Ratio (Numerator)
⎟
⎠
⎞
⎜
⎝
⎛
A
B
Pn203
Electronic Gear Ratio (Denominator)
Parameter
Signal
Setting
Control Mode
Pn202
Electronic Gear Ratio
(Numerator)
Range: 1 to 65535
Default Setting: 1
Position Control and
Programming
Pn203
Electronic Gear Ratio
(Denominator)
Range: 1 to 65535
Default Setting: 1
Position Control and
Programming
Set the electronic gear ratio according to equipment specifications.
M
Electronic
gear
B
_
A
Motor
FSP Amplifier
Reference
input pulse
Electronic Gear Ratio =
⎟
⎠
⎞
⎜
⎝
⎛
A
B
=
203
Pn
202
Pn
• B = [(Number of encoder pulses) × 4] × [motor speed]
• A = [Reference units (travel distance per load shaft revolution)] ×
[load shaft revolution speed]
Electronic Gear Setting Examples
The following examples show electronic gear settings for different load
mechanisms.
Ball Screws
Travel distance per load shaft revolution =
in
00004
.
0
in
24
.
0
= 6000
Electronic gear ratio
=
⎟
⎠
⎞
⎜
⎝
⎛
A
B
=
6000
1
x
4
x
2048
=
203
Pn
202
Pn
Pn202 8192
Preset
Values
Pn203 6000